Part Number Hot Search : 
ADTR2 2SC5343 RXE010 S2561 LM7918 EPA240B ST115005 RPM2AP24
Product Description
Full Text Search
 

To Download E3X-NA11 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  1 simple fiber amplifier e3x-sd/-na the highest level of power and precision in the industry with ?giga ray? giga power lighting element ? stable detection of minute objects even when the sensor is covered with dust and oil in severe environments. ? quick-tuning to automatically adjust light level and set threshold value. ? use the one-key one-function feature for quick, easy operation. ? reasonable price. ordering information amplifier units [refer to dimensions on page 13 .] digital display and direct key setting *an amplifier unit connector (sold separately) is required. bar display and adjuster setting *1. an amplifier unit connector (sold separately) is required. *2. a sensor i/o connector (sold separately) is required. item appearance connection method ratings and specifications model npn output pnp output standard models pre-wired (2 m) --- e3x-sd21 2m e3x-sd51 2m wire-saving connector * e3x-sd7 e3x-sd9 item appearance connection method ratings and specifications model npn output pnp output standard models pre-wired (2 m) --- E3X-NA11 2m e3x-na41 2m wire-saving connector *1 e3x-na6 e3x-na8 high-speed detection models pre-wired (2 m) response time: 20 s E3X-NA11f 2m e3x-na41f 2m water-resistant models pre-wired (2 m) degree of protection: ip66 E3X-NA11v 2m e3x-na41v 2m connector (m8) *2 e3x-na14v e3x-na44v
e3x-sd/-na 2 amplifier unit connectors (sold separately) note: protective seals provided. [refer to dimensions on page 17 .] sensor i/o connectors (models for connectors: a connector is not provided with th e amplifier unit. be sure to order a connector separately.) [refer to dimensions on xs3 .] accessories (sold separately) item appearance cable length no. of conductors model master connector 2 m 3 e3x-cn11 slave connector 1 e3x-cn12 size cable specifications appearance cable type model m8 standard cable 2 m four- conductor cable xs3f-m421-402-a 5 m xs3f-m421-405-a 2 m xs3f-m422-402-a 5 m xs3f-m422-405-a ordering precautions for amplifier units connectors amplifier units applicable connectors (sold separately) type npn pnp + master connector slave connector a connector is not provided with the amplifier unit. refer to the tables at the right when placing an order. standard models e3x-sd7 e3x-sd9 e3x-cn11 (3-wire) e3x-cn12 (1-wire) e3x-na6 e3x-na8 when using 5 amplifier units 5 amplifier units + 1 master connector + 4 slave connectors straight connector l-shaped connector mounting brackets a mounting bracket is not provided with the amplifier unit. order a mounting bracket separately if required. [refer to dimensions on page 17 .] appearance applicable models model quantity e3x-sd @ e3x-na @ e3x-na @ f e39-l143 1 e3x-na @ v e39-l148 end plate end plates are not provided with the amplifier unit. order end plates separately if required. [refer to dimensions on page 17 .] appearance model quantity pfp-m 1
e3x-sd/-na 3 ratings and specifications amplifier units ? 1. when there are 8 or more e3x-na amplifiers mounted side-by-side, the response time will be 350 s max. ? 2. mutual interference prevention is effective when e3x-sd/-na-s eries amplifiers are gang-mounted without other e3x-series ampl ifiers. ? 3. water-resistant models and models with conn ectors have a dielectric strength of 500 vac. ? 4. add 10 g for water-resistant models. amplifier unit connectors (wire-saving connectors) type digital display and direct key setting bar display and adjuster setting standard models standard models high-speed detection models water-resistant models model e3x-sd @ e3x-na @ e3x-na @ f e3x-na @ v item light source (wavelength) red, 4-element led (625 nm) red led (680 nm) power supply voltage 12 to 24 vdc 10%, ripple (p-p): 10% max. power consumption/ current consumption 960 mw max. (power supply voltage: 24 v, current consumption: 40 ma max.) (power supply voltage: 12 v, current consumption: 80 ma max.) 960 mw max. (current consumption: 40 ma max.) control output open-collector output (npn or pnp) load power supply: 26.4 v max., load current: 50 ma max. (residual voltage: 1.5 v max.) light-on/dark-on mode selector open-collector output (npn or pnp) load power supply: 26.4 v max., load current: 50 ma max. (residual voltage: 1 v max.) light-on/dark-on mode selector. response time operate or reset: 200 s max. ( ? 1) operate: 20 s max. reset: 30 s max. operate or reset: 200 s max. ( ? 1) sensitivity adjustment up/down direct key setting, teaching with/without a workpiece, automatic teaching 8-turn sensitivity adjuster (with indicator) protection circuits power supply reverse polarity protection, output short-circuit protection, output reverse polarity protection power supply reverse polarity protection, output short-circuit protection timer function --- no timer, off-delay timer; or timer selector (timer time: 40 ms (fixed)) mutual interference prevention up to 5 amplifiers (optically synchronized) ( ? 2) none up to 5 amplifiers (optical- ly synchronized) ( ? 2) ambient illumination receiver side incandescent lamp: 10,000 lux max. sunlight: 20,000 lux max. number of gang-mounted amplifiers 16 max. (the ambient temperature specification depends on the number of gang-mounted amplifiers.) ambient temperature range operating: groups of 1 to 3 amplifiers: ? 25 c to 55 c groups of 4 to 11 amplifiers: ? 25 c to 50 c groups of 12 to 16 amplifiers: ? 25 c to 45 c storage: ? 30 c to 70 c (with no icing or condensation) ambient humidity range operating and storage: 35% to 85% (with no condensation) insulation resistance 20 m . min. (at 500 vdc) dielectric strength 1,000 vac at 50/60 hz for 1 minute ( ? 3) vibration resistance destruction: 10 to 55 hz with a 1.5-mm double amplitude for 2 hours each in x, y and z directions shock resistance destruction: 500 m/s 2 , for 3 times each in x, y and z directions degree of protection iec 60529 ip50 (with protective cover attached) iec 60529 ip66 (with protective cover at- tached) connection method pre-wired (standard cable length: 2 m), or connector weight (packed state) ( ? 4) pre-wired model: approx. 100 g, model with connector: approx. 55 g material case polybutylene terephthalate (pbt) cover polycarbonate (pc) polyethersulfone (pes) accessories instruction manual item model e3x-cn11 e3x-cn12 rated current 2.5 a rated voltage 50 v contact resistance 20 m max. (20 mvdc max., 100 ma max.) (the above figure is for connection to the amplifier unit and t he adjacent connector. it does not include the conductor resista nce of the cable.) number of insertions destruction: 50 times (for connection to the amplifier unit and the adjacent connector) material housing polybutylene terephthalate (pbt) contact phosphor bronze/gold-plated nickel weight (packed state) approx. 55 g approx. 25 g
e3x-sd/-na 4 sensing distance amplifier unit sensing distance (unit: mm) fiber unit e3x-sd @ e3x-na @ e3x-na @ f e3x-na @ v screw-shaped model sensing method size sensing direction model standard models high-speed detection models water-resistance models through- beam models m3 straight e32-t21r 2m 120 36 60 m4 right angle e32-t11n 2m 530 160 280 straight e32-t11r 2m 560 160 280 e32-tc200 2m 800 240 400 e32-t11l 2m 1,400 420 700 reflective models m3 right angle e32-c31n 2m 25 7.5 13 straight e32-d21r 2m 30 10 15 e32-c31 2m 80 26 40 m4 e32-d211r 2m 30 10 15 m6 right angle e32-d11n 2m 170 50 90 e32-c11n 2m 170 50 85 straight e32-d11r 2m 180 60 90 e32-dc200 2m 300 100 150 e32-cc200 2m 300 100 150 e32-d11l 2m 400 130 200 amplifier unit sensing distance (unit: mm) fiber unit e3x-sd @ e3x-na @ e3x-na @ f e3x-na @ v flat model sensing method sensing direction size model standard models high-speed detection models water-resistance models through- beam models top view standard e32-t15xr 2m 560 160 280 small e32-t25xr 2m 120 36 60 side view standard e32-t15yr 2m 220 66 110 small e32-t25yr 2m 60 18 30 flat view standard e32-t15zr 2m 220 66 110 small e32-t25zr 2m 60 18 30 reflective models top view standard e32-d15xr 2m 180 60 90 small e32-d25xr 2m 30 10 15 side view standard e32-d15yr 2m 40 10 20 small e32-d25yr 2m 8 2.4 4 flat view standard e32-d15zr 2m 40 10 20 small e32-d25zr 2m 8 2.4 4 amplifier unit sensing distance (unit: mm) fiber unit e3x-sd @ e3x-na @ e3x-na @ f e3x-na @ v cylindrical model sensing method sensing direction size model standard models high-speed detection models water-resistance models through- beam models top view 1 e32-t223r 2m 120 36 60 3 e32-t12r 2m 560 160 280 side view 1 e32-t24r 2m 60 18 30 3 e32-t14lr 2m 220 66 110 reflective models top view 1.5 e32-d22b 2m 30 10 15 2 e32-d32 2m 80 26 40 3 e32-d22r 2m 30 10 15 e32-d32l 2m 160 50 80 side view 2 e32-d24r 2m 14 4.6 7 6 e32-d14lr 2m 32 10 16 for information on fibe r units, re fer to the fiber sensors best selection catalog (cat. no. e353).
e3x-sd/-na 5 ? the fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm. amplifier unit sensing distance (unit: mm) fiber unit e3x-sd @ e3x-na @ e3x-na @ f e3x-na @ v model equipped with sleeve sensing method sleeve size mounting size model standard models high-speed detection models water-resistance models through- beam models 0.25 5 3 e32-t333-s5 1m 10 3 5 0.5 40 e32-t33 1m 40 13.5 20 0.9 40 m3 e32-tc200f4r 2m 120 36 60 1.2 90 m4 e32-tc200br 2m 560 160 280 reflective models 0.5 15 2 e32-d331 2m 3 1 1.5 0.8 15 3 e32-d33 2m 16 4 10 1.2 40 m3 e32-dc200f4r 2m 30 10 15 2.5 90 m6 e32-dc200br 2m 180 60 90 amplifier unit sensing distance (unit: mm) fiber unit e3x-sd @ e3x-na @ e3x-na @ f e3x-na @ v movable section (flexibility) sensing method shape size model standard models high-speed detection models water-resistance models through- beam models screw-shaped model m3 e32-t21 2m 200 60 100 m4 e32-t11 2m 720 200 360 cylindrical model 1.5 e32-t22b 2m 200 60 100 3 e32-t12b 2m 720 200 360 flat model standard e32-t15xb 2m 720 200 360 small e32-t25xb 2m 150 40 75 reflective models screw-shaped model m3 e32-d21 2m 30 10 15 m4 e32-d21b 2m 70 20 35 m6 e32-d11 2m 180 60 90 cylindrical model 1.5 e32-d22b 2m 30 10 15 3 e32-d221b 2m 70 20 35 flat model standard e32-d15xb 2m 180 60 90 small e32-d25xb 2m 50 16 25 amplifier unit sensing distance (unit: mm) fiber unit e3x-sd @ e3x-na @ e3x-na @ f e3x-na @ v heat-resistance model sensing method operating temperature lens model standard models high-speed detection models water-resistance models through- beam models 100 c --- e32-t51r 2m 400 120 225 lens e32-t51r 2m + e39-f1 2,000 720 1,650 high-power lens e32-t51r 2m + e39-f16 4,000 ? 1,560 2,900 150 c --- e32-t51 2m 800 240 400 lens e32-t51 2m + e39-f1-33 2,400 720 1,400 high-power lens e32-t51 2m + e39-f16 4,000 ? 3,120 4,000 ? --- e32-t54 2m 260 70 130 200 c e32-t81r-s 2m 360 100 180 lens e32-t61-s 2m + e39-f1 4,000 ? 1,800 3,000 350 c --- e32-t61-s 2m 600 180 300 high-power lens e32-t61-s 2m + e39-f16 4,000 ? 2,340 3,900 reflective models 100 c --- e32-d51r 2m 140 42 70 150 c e32-d51 2m 240 80 120 200 c e32-d81r 2m 90 27 45 350 c e32-d61 2m 90 27 45 400 c e32-d73 2m 60 18 30 for information on fibe r units, refer to the fiber sensors best selection catalog (cat. no. e353).
e3x-sd/-na 6 amplifier unit sensing distance (unit: mm) fiber unit e3x-sd @ e3x-na @ e3x-na @ f e3x-na @ v chemical-resistance / oil-resistance model sensing method type model standard models high-speed detection models water-resistance models through- beam models 5 e32-t12f 2m 3,200 960 1,600 7.2 e32-t11f 2m 2,100 760 1,050 5 heat-resistance e32-t51f 2m 1,400 400 700 5 side view e32-t14f 2m 400 120 200 m4 chemical-resistance cable e32-t11u 2m 720 200 360 m4 right angle chemical-resistance cable e32-t11nu 2m 400 120 210 reflective models 6 e32-d12f 2m 100 32 50 7 side view e32-d14f 2m 40 13 20 m6 chemical-resistance cable e32-d11u 2m 180 60 90 amplifier unit sensing distance (unit: mm) fiber unit e3x-sd @ e3x-na @ e3x-na @ f e3x-na @ v vacuum-resistance model sensing method operating ambient temperature sensing direction model standard models high-speed detection models water-resistance models through- beam models 120 c top view e32-t51v 1m 200 --- 100 e32-t51v 1m + e39-f1v 1,200 --- 600 right angle e32-t54v 1m 130 --- 65 200 c e32-t84sv 1m 500 --- 250 for information on fibe r units, re fer to the fiber sensors best selection catalog (cat. no. e353).
e3x-sd/-na 7 ? 1. the fiber length is 10 m on each side, so the sensing distance is given as 20,000 mm. ? 2. the fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm. amplifier unit sensing distance (unit: mm) fiber unit e3x-sd @ e3x-na @ e3x-na @ f e3x-na @ v long distance/dust resistance (high-power), detection through gaps (narrow vision field) sensing method type sensing direction/ lens type model standard models high-speed detection models water-resistance models through- beam models high-power (integrated unit) top view e32-t17l 10m 20,000 ? 1 8,400 14,000 side view e32-t14 2m 3,600 1,080 1,800 high-power (with lens unit) high-power e32-t11n 2m + e39-f1 3,700 1,110 2,100 ultrahigh-power e32-t11n 2m + e39-f16 4,000 ? 2 2,000 3,600 high-power e32-t11r 2m + e39-f1 4,000 ? 2 1,260 2,100 ultrahigh-power e32-t11r 2m + e39-f16 4,000 ? 2 2,000 3,600 side view e32-t11r 2m + e39-f2 440 130 220 high-power e32-tc200 2m + e39-f1 4,000 ? 2 1,800 3,000 ultrahigh-power e32-tc200 2m + e39-f16 4,000 ? 2 3,000 4,000 ? 2 side view e32-tc200 2m + e39-f2 700 210 350 high-power e32-t11 2m + e39-f1 4,000 ? 2 1,200 2,000 ultrahigh-power e32-t11 2m + e39-f16 4,000 ? 2 2,600 4,000 ? 2 side view e32-t11 2m + e39-f2 720 200 360 high-power e32-t11u 2m + e39-f1 3,600 1,080 2,000 ultrahigh-power e32-t11u 2m + e39-f16 4,000 ? 2 2,600 4,000 ? 2 side view e32-t11u 2m + e39-f2 660 198 330 high-power e32-t11nu 2m + e39-f1 1,800 700 1,500 ultrahigh-power e32-t11nu 2m + e39-f16 4,000 ? 2 1,500 2,700 high-power e32-t81r-s 2m + e39-f1 1,800 630 1,100 ultrahigh-power e32-t81r-s 2m + e39-f16 4,000 ? 2 1,300 2,300 side view e32-t81r-s 2m + e39-f2 280 84 140 high-power e32-t61-s 2m + e39-f1 4,000 ? 2 1,800 3,000 ultrahigh-power e32-t61-s 2m + e39-f16 4,000 ? 2 2,340 3,900 side view e32-t61-s 2m + e39-f2 780 260 390 narrow vision field (aperture angle: 4 ) top view e32-t22s 2m 2,000 600 1,000 side view e32-t24s 2m 1,400 420 700 reflective models high-power top view e32-d16 2m 800 140 40 to 400 amplifier unit sensing distance (unit: mm) fiber unit e3x-sd @ e3x-na @ e3x-na @ f e3x-na @ v minute object detection (small-spot model) sensing method spot diameter (mm) focal length (mm) model standard models high-speed detection models water-resistance models reflective models 0.1 to 0.6 (variable) 6 to 15 e32-c42 1m + e39-f3a spot diameter of 0.1 to 0.6 mm at 6 to 15 mm 0.1 5 e32-c42s 1m spot diameter of 0.1 mm at 5 mm 7 e32-c41 1m + e39-f3a-5 spot diameter of 0.1 mm at 7 mm 0.2 17 e32-c41 1m + e39-f3b spot diameter of 0.2 mm at 17 mm 0.5 7 e32-c31 2m + e39-f3a-5 spot diameter of 0.5 mm at 7 mm 17 e32-c31 2m + e39-f3b spot diameter of 0.5 mm at 17 mm 6 50 e32-l15 2m spot diameter of 6 mm at 50 mm 4 parallel light 0 to 20 e32-c31 2m + e39-f3c spot diameter of 4 mm max. at 0 to 20 mm 3 50 e32-c11n 2m + e39-f18 spot diameter of 3 mm at 50 mm e32-cc200 2m + e39-f18 spot diameter of 3 mm at 50 mm for information on fibe r units, refer to the fiber sensors best selection catalog (cat. no. e353).
e3x-sd/-na 8 ? 1. when using a highly reflective object, light re flected from the object may affect the sensor. ? 2. film detection may not be effective for some types of film. confirm operation in advance. amplifier unit sensing distance (unit: mm) fiber unit e3x-sd @ e3x-na @ e3x-na @ f e3x-na @ v area-sensing (area beam) sensing method area range sensing direction model standard models high-speed detection models water-resistance models through- beam models 11 mm side view e32-t16pr 2m 800 260 450 flat view e32-t16jr 2m 700 220 390 30 mm side view e32-t16wr 2m 1,380 400 690 reflective models 11 mm e32-d36p1 2m 150 50 75 amplifier unit sensing distance (unit: mm) fiber unit e3x-sd @ e3x-na @ e3x-na @ f e3x-na @ v detection without background inte rference (convergent-reflective) sensing method sensing detection size model standard models high-speed detection models water-resistance models reflective models flat view standard e32-l16-n 2m 0 to 15 0 to 12 0 to 15 small e32-l24s 2m 0 to 4 top view --- e32-l25l 2m 5.4 to 9 (center 7.2) 5.4 to 8 (center 7.2) 5.4 to 9 (center 7.2) flat view e32-l24l 2m 2 to 6 (center 4) amplifier unit sensing distance (unit: mm) fiber unit e3x-sd @ e3x-na @ e3x-na @ f e3x-na @ v detection of transparent objects (retro-reflective) sensing method type model standard models high-speed detection models water-resistance models retro- reflective models ? 1 square e32-r16 5m + e39-r1 (attached) 1,500 1,000 150 to 1,500 small e32-r21 2m + e39-r3 (attached) 10 to 250 250 10 to 250 film detection ? 2 e32-c31 2m + e39-f3r + e39-rp1 450 135 225 e32-c31 2m + e39-f3r + e39-rsp1 220 65 110 for information on fibe r units, re fer to the fiber sensors best selection catalog (cat. no. e353).
e3x-sd/-na 9 amplifier unit sensing distance (unit: mm) fiber unit e3x-sd @ e3x-na @ e3x-na @ f e3x-na @ v fpd / semiconductor / solar battery industry sensing method application operating temperature model standard models high-speed detection models water-resistance models reflective models glass substrate alignment 70 c e32-l16-n 2m 0 to 15 e32-a08 2m 10 to 20 300 c e32-a08h2 3m 10 to 20 glass detection 70 c e32-l16-n 2m 0 to 15 glass substrate mapping 70 c e32-a09 2m 15 to 38 (center 25) 150 c e32-a09h 2m 15 to 38 (center 25) 300 c e32-a09h2 2m 20 to 30 (center 25) wet process 60 c e32-l11fp 5m 8 to 20 mm from end of lens (recommended: 11 mm) 19 to 31 mm from center point a of mounting hole (recommended: 22 mm) 70 c e32-l12fs 5m 8 to 20 mm from end of lens (recommended: 11 mm) 32 to 44 mm from center point a of mounting hole (recommended: 35 mm) 85 c e32-l11fs 5m 8 to 20 mm from end of lens (recommended: 11 mm) 32 to 44 mm from center point a of mounting hole (recommended: 35 mm) through- beam models wafer mapping 70 c e32-a03 2m 890 267 445 e32-a03-1 2m 890 267 445 e32-a04 2m 340 102 170 e32-a04-1 2m 340 102 170 amplifier unit sensing distance (unit: mm) fiber unit e3x-sd @ e3x-na @ e3x-na @ f e3x-na @ v liquid-level detection model sensing method sensing direction pipe diameter model standard models high-speed detection models water-resistance models reflective models mounted to pipe no limit e32-d36t 5m applicable pipe: transparent (n o restriction on diameter) 8 to 10 mm e32-l25t 2m applicable pipe: transparent pipe with diameter of 8 to 10 mm, recommended pipe wall thickness: 1 mm wet --- e32-d82f1 4m wet model for information on fibe r units, refer to the fiber sensors best selection catalog (cat. no. e353).
e3x-sd/-na 10 i/o circuit diagrams note: timing charts for timer settings (t: set time) plug (sensor i/o connector) output form model output transistor operation mode timing charts operation selector output circuit npn output e3x-sd21 e3x-sd7 E3X-NA11 e3x-na6 E3X-NA11f E3X-NA11v e3x-na14v light-on light on (l-on) dark-on dark on (d-on) pnp output e3x-sd51 e3x-sd9 e3x-na41 e3x-na8 e3x-na41f e3x-na41v e3x-na44v light-on light on (l-on) dark-on dark on (d-on) off delay incident light n o incident light o n off o n off operate reset operation indicator (orange) (bet w een b ro w n and b lack leads) o u tp u t transistor load (relay) t black bro w n bl u e control o u tp u t operation indicator (orange) photo- electric sensor main circ u it load 12 to 24 v dc 1 4 3 ? m 8 connector pin arrangement n ote: pin 2 is not u sed. 1 2 4 3   n ot present on the e3x- n a. t incident light n o incident light o n off o n off operate reset operation indicator (orange) (bet w een b ro w n and b lack leads) o u tp u t transistor load (relay) t incident light n o incident light o n off o n off operate reset operation indicator (orange) (bet w een b l u e and b lack leads) o u tp u t transistor load (relay) 1 4 3 1 2 4 3  n ot present on the e3x- n a.  black bro w n bl u e control o u tp u t operation indicator (orange) photo- electric sensor main circ u it load 12 to 24 v dc ? m 8 connector pin arrangement n ote: pin 2 is not u sed. t incident light n o incident light o n off o n off operate reset operation indicator (orange) (bet w een b l u e and b lack leads) o u tp u t transistor load (relay) incident light n o incident light o n off o n off l-o n d-o n t t note: pin 2 is not used. classification wire color connection pin application dc brown 1 power supply (+v) white 2 --- blue 3 power supply (0 v) black 4 output 2 4 1 3 1 2 3 4 bro w n w hite bl u e black w ire color terminal n u m b er xs3f-m421-402-a xs3f-m421-405-a xs3f-m422-402-a xs3f-m422-405-a
e3x-sd/-na 11 safety precautions this product is not designed or rated for ensuring safety of pers ons either directly or indirectly. do not use it for such purposes. do not exceed the rated voltage. excess voltage may result in malfunction or fire. do not use an ac power supply. using an ac power su pply may result in rupturing. high-temperature environm ents may result in burn injury. the following precautions must be observed to ensure safety. 1. do not use the product in locations where flammable or explosive gas is present. 2. do not use the product in locations subject to splashing water, oil, or chemicals, or in locations subject to steam. 3. do not attempt to disassemble, repair, or modify the product. 4. do not apply voltage or current in excess of the rated ranges. 5. do not use the product in atmospheres or environments that exceed product ratings. 6. do not wire the product incorrectly, such as using incorrect power supply polarity. 7. connect the load properly. 8. do not short-circuit both ends of the load. 9. do not use the product if the case is damaged. 10. when disposing of the product, dispose of it as industrial waste. 11. do not use the product in locations subject to direct sunlight. 12. the surface temperature of the product may rise as a result of the ambient temperat ure, power supply, or other usage conditions. use caution when performing maintenance and washing. failure to do so may result in burn injury. do not use the product in atmo spheres or environments that exceed product ratings. amplifier units designing communications hole the hole on the side of the amplif ier unit is a communications hole for preventing mutual interference when amplifier units are mounted side-by-side. t he e3x-mc11 mobile console (sold separately) cannot be used. if an excessive amount of light is received via the sensor, the mutual interference prevention function may not work. in this case, make the appropriate adju stments using the sensitivity adjuster. mutual interference prevention is effective when e3x-sd/- na-series amplifiers are gang-mounted without other e3x- series amplifiers. mounting din track mounting/removal mounting amplifier units 1. mount the amplifier units one at a time onto the din track. 2. slide the amplifier units t ogether, line up the clips, and press the amplifier units togethe r until they click into place. removing amplifier units slide amplifier units away from each other, and remove from the din track one at a time. (do not attempt to remove amplifier units from the din tr ack without separating them first.) warning caution precautions for safe use precautions fo r correct use note 1. the specifications for ambient temp erature will vary according to the number of amplifier units used together. for details, refer to ratings and specifications . 2. always turn off the power supply before mounting or removing amplifier units. click into place clip
e3x-sd/-na 12 fiber connection and disconnection the e3x amplifier unit has a lock lever. connect or disconnect the fibers to or from the e3x amplifier unit using the following procedures: 1. connection open the protective cover, insert the fibers according to the fiber insertion marks on the side of the amplifier unit, and lower the lock lever. note: if one of the fibers from the fiber unit has a white line, such as with a coaxial sensor, that fiber is for the emitter. insert it into the emitter section. refer to dimensions for the fiber unit to see if there is an emitter fiber. 2. disconnection remove the protective cover and raise the lock lever to pull out the fiber. note: to maintain the fiber properti es, confirm that the lock is released before removing the fiber. 3. precautions for fiber connection/disconnection be sure to lock or unlock the lock lever within an ambient temperature range between ? 10 c and 40 c. operating environment ambient conditions if dust or dirt adhere to the hole for optical communications, it may prevent normal communications. be sure to remove any dust or dirt before using the units. other protective cover be sure to mount the pr otective cover before use. amplifier units with connectors mounting mounting connectors 1. insert the master or slave c onnector into the amplifier unit until it clicks into place. 2. join amplifier units together as required after all the master and slave connectors have been inserted. 3. attach the stickers (provided as accessories) to the sides of master and slave connectors that are not connected to other connectors. note: attach the stickers to the sides with grooves. removing connectors 1. slide the slave amplifier unit for which the connector is to be removed away from the rest of the group. 2. after the amplifier unit ha s been separated, press down on the lever on the connector and remove it. (do not attempt to remove connectors without separating them from other amplifier units first.) mounting end plate (pfp-m) depending on how it is mounted, an amplifier unit may move during operation. in this case, use an end plate. before mounting an end plate, remove the clip from the master amplifier unit using a nipper or similar tool. the clip can also be removed using the following mechanism, which is incorporated in the construction of the section underneath the clip. 1. insert the clip to be removed into the slit underneath the clip on another amplifier unit. 2. remove the clip by rotating the amplifier unit. pull strengths for connectors (including cables) e3x-cn11: 30 n max. e3x-cn12: 12 n max. lock le v er fi b er fi b er insertion mark 10.7 mm insertion position locked unlocked protecti v e co v er insert sticker sticker remo v e le v er press do w n clip rotate
e3x-sd/-na 13 dimensions amplifier units (unit: mm) tolerance class it16 applies to dimensions in this sheet unless otherwise specified. 1 8 0 4.3 8 10.7 10 1 0 3.4 22.4 4.4 13 64.3 6 4 . 3 16 10.75 16 8 10.7 3 12 8 .95 1 2 8 . 9 5 3 12 8 .95 1 2 8 . 9 5 2.4 4 2.4 4 10.75 16 10 10 l (9) 3.4 31.5 3 1 . 5 (9) 3.4 31.5 3 1 . 5 (9.4) 1 8 0 93.75 9 3 . 7 5 10 1 0 15 93.75 9 3 . 7 5 13 12.4 30.4 64.3 6 4 . 3 operation indicator t w o, 2.4 dia. t w o, 2.4 dia. hole for optical comm u nications ? hole for optical comm u nications ? center of di n track di n track (sold separately) pfp- @ n fi b er attachment mo u nted (e39-f9) end plate (sold separately) pfp-m mo u nting bracket (e39-l143) sus304 stainless steel (sold separately) fi b er attachment mo u nted (e39-f9) t w o, m3 mountin g holes ? there is no hole for e3x- n a @ f models. with mountin g bracket attached multiple connection dia g ram din track mountin g v inyl-ins u lated ro u nd ca b le 4 dia. ca b le / 3 cond u ctors / standard length: 2 m (cond u ctor cross section: 0.2 mm 2 , ins u lator diameter: 1.1 mm) t w o, 3.2 dia. holes amplifier units with cables e3x-sd21 e3x-sd51 E3X-NA11 E3X-NA11f e3x-na41 e3x-na41f the number of expansion l (mm) 1 10 2 20 3 30 4 40 5 50 6 60 7 70 8 80 9 90 10 100 note: when using e39-l143 mounting brackets, there will be small gaps between the amplifier units if they are mounted side by side.
e3x-sd/-na 14 amplifier units with c onnectors e3x-sd7 e3x-sd9 e3x-na6 e3x-na8 4.3 8 10.7 10 1 0 3.4 22.4 4.4 13 64.3 6 4 . 3 16 16 8 10.7 3 12 8 .95 1 2 8 . 9 5 3 12 8 .95 1 2 8 . 9 5 16 10 10 l (9) 3.4 31.5 3 1 . 5 (9) 3.4 31.5 3 1 . 5 (9.4) 1 8 0 93.75 9 3 . 7 5 10 1 0 15 93.75 9 3 . 7 5 13 12.4 30.4 64.3 6 4 . 3 operation indicator t w o, 2.4 dia. t w o, 2.4 dia. hole for optical comm u nications center of di n track di n track (sold separately) pfp- @ n fi b er attachment mo u nted (e39-f9) end plate (sold separately) pfp-m mo u nting bracket (e39-l143) sus304 stainless steel (sold separately) fi b er attachment mo u nted (e39-f9) t w o, m3 mountin g holes with mountin g bracket attached multiple connection dia g ram din track mountin g t w o, 3.2 dia. holes 1 8 0 a dia. ? 12.95 hole for optical comm u nications a dia. ? 12.95 ? cable diameters e3x-cn11 (3 conductors) 4.0 dia. e3x-cn12 (1 conductor) 2.6 dia. the number of expansion l (mm) 1 10 2 20 3 30 4 40 5 50 6 60 7 70 8 80 9 90 10 100 note: when using e39-l143 mounting brackets, there will be small gaps between the amplifier units if they are mounted side by side.
e3x-sd/-na 15 9.2 2 8 .65 25.95 8 10.7 11.2 6.9 12 1 2 12 1 2 8 10.7 14.4 9.5 67.2 6 7 . 2 16 16 23.9 6.6 11.2 5.4 3.4 16 14.4 31.9 67.2 6 7 . 2 1 8 152.3 1 5 2 . 3 6.9 152.3 1 5 2 . 3 105.9 1 0 5 . 9 105.9 1 0 5 . 9 10 10 l 1 8 0 1 8 0 4.3 3.4 33 3 3 (9) 3.4 33 3 3 (9) operation indicator incident le v el indicators v inyl-ins u lated ro u nd ca b le 4 dia. ca b le / 3 cond u ctors / standard length: 2 m (cond u ctor cross section: 0.45 mm 2 , ins u lator diameter: 1.1 mm) din track mountin g t w o, 2.4 dia. center of di n track di n track (sold separately) pfp- @ n fi b er attachment mo u nted (e39-f9) end plate (sold separately) pfp-m multiple connection dia g ram hole for optical comm u nications hole for optical comm u nications mo u nting bracket (e39-l14 8 ) sus304 stainless steel (sold separately) with mountin g bracket attached fi b er attachment mo u nted (e39-f9) t w o, m3 mountin g holes t w o, 2.4 dia. area of di g ital indication amplifier units with cables, water-resistant models E3X-NA11v e3x-na41v the number of expansion l (mm) 1 12 2 24 3 36 4 48 5 60 6 72 7 84 8 96 9 108 10 120
e3x-sd/-na 16 9.2 2 8 .65 25.95 8 10.7 11.2 6.9 12 1 2 12 1 2 8 10.7 14.4 9.5 67.2 6 7 . 2 16 16 23.9 11 11.2 5.4 3.4 16 14.4 31.9 67.2 6 7 . 2 1 8 152.3 1 5 2 . 3 6.9 152.3 1 5 2 . 3 105.9 1 0 5 . 9 105.9 1 0 5 . 9 10 10 l 1 8 0 1 8 0 4.3 3.4 33 3 3 (9) 3.4 33 3 3 (9) operation indicator incident le v el indicators din track mountin g t w o, 2.4 dia. center of di n track di n track (sold separately) pfp- @ n fi b er attachment mo u nted (e39-f9) end plate (sold separately) pfp-m multiple connection dia g ram hole for optical comm u nications hole for optical comm u nications mo u nting bracket (e39-l14 8 ) sus304 stainless steel (sold separately) with mountin g bracket attached fi b er attachment mo u nted (e39-f9) t w o, m3 mountin g holes t w o, 2.4 dia. area of di g ital indication amplifier units with c onnectors, water-resistant models e3x-na14v e3x-na44v the number of expansion l (mm) 1 12 2 24 3 36 4 48 5 60 6 72 7 84 8 96 9 108 10 120
e3x-sd/-na 17 amplifier unit connectors (wire-saving connectors) accessories (sold separately) master connector e3x-cn11 (7) 2,000 +50 0 ? ? e3x-c n 11: 4 dia. 4 d i a . ca b le / 3 cond u ctors 3 c o n d u c t o r s / standard length: 2 m (cond u ctor cross section: 0.2 mm 2 (a w g24), ins u lator diameter: 1.1 mm) edge of amplifier slave connector e3x-cn12 (7) 2,000 +50 0 ? ? e3x-c n 12: 2.6 dia. 2 . 6 d i a . ca b le / 1 cond u ctor 1 c o n d u c t o r / standard length: 2 m (cond u ctor cross section: 0.2 mm 2 (a w g24), ins u lator diameter: 1.1 mm) edge of amplifier mounting brackets e39-l143 fo u r, r1.7 7 3.4 1 3 16 3 10 max. 7 10.3 7.3 5.3 (10.3) 2.5 34. 8 22 16 26. 8 3 t w o, 3.2 dia. 3.4 1 t w o, m3 16 0.1 mo u nting holes material: stainless steel (sus304) end plates pfp-m 50 11.5 10 m4 8 panhead scre w m4 spring w asher 4. 8 1.3 1. 8 1. 8 1 6.2 10 35.5 35.3
e3x-sd/-na 18 nomenclature operating procedure e3x-sd the sensitivity can be set with the up and down keys similar to using an adjuster knob. the sensitivity can also be easily set by using the following two teaching functions. two points (one with the work piece and the other without) are detected, and the oper ating level is set to the midpoint. light level is also automatically set to the optimal value. changes within a time are detected, and the operating level is set to the midpoint between the maximum and the minimum values of the changes. this setting is optimal for when the workpieces cannot be stopped. execute automatic teaching again if the incident light level is not automatically set to the optimal value. e3x-na a bar display (with four green and one red) showing excess gain is provided in addition to the orange operation indicator. use these when adjusting the light axis and setting the sensitivity at setup. digital threshold v al u e adj u stment (up/do wn ) teaching stat u s indication(orange) operation selector use to s w itch b et w een light-o n and dark-o n lock le v er digital incident light le v el display or digital threshold v al u e display (red) display of contents of f u nctions d u ring operation light-o n and dark-o n indicator teaching b u tton the sensiti v ity and threshold v al u e can b e set a u tomatically. operation indicator (orange) amplifier units e3x-sd e3x-na incident le v el indicators lock le v er sensiti v ity indicator 8 -t u rn sensiti v ity adj u ster operation indicator operation selector use to s w itch b et w een light-o n and dark-o n timer s w itch o n : timer f u nction is o n . off: timer f u nction is off. operation description button/key press the teach button with the workpiece. press the teach button without the workpiece. operation description button/key press the teach button for 3 s min. let the workpiece pass while the button is pressed. sensiti v ity setting 1 2-1. teaching w ith/ w itho u t a w orkpiece teach teach 2-2. a u tomatic teaching teach display/indicator status (for l/on) excess gain level description approx. 120% min. stable incident light approx. 110% to 120% approx. 90% to 110% unstable incident light or unstable interrupted light approx. 80% to 90% stable interrupted light approx. 80% max. displays 1 operation indicator excess gain le v el display
r ead and u nderstand this document please read and understand this document before using the products. pl ease consult your omron representative if you have any qu estions or comments. warranty omron?s exclusive warranty is that the pr oducts are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by omron. omron makes no warranty or representation, express or implied, regarding non-infringement, merchantability, or fitness for particular purpose of the products. any buyer or user acknowledges that the buyer or user alone has determined that the pr oducts will suitably meet the requirements of their intended use. omron disclaims all other warranties, express or implied. limitations of liability omron shall not be responsible for special, indirect , or consequential damages, loss of profits or commercial loss in any way connected with the products, whether such claim is based on contract, warranty, negligence, or strict liability. in no event shall responsibility of omron for any act exceed the individual price of the product on which liability is asserted . in no event shall omron be responsible for warranty, repair, or other claims regarding the products unless omron?s analysis confirms that the products were pro perly handled, stored, installed, and maintained and not subject to contamination, abuse, misuse, or inappropriate modification or repair. suitability for use the products contained in this document are not safety rated. they are not designed or rated for ensuring safety of persons, and should not be relied upon as a safety component or protective device for such purposes. please refer to separate cata logs for omron's safety rated products. omron shall not be responsible for conformi ty with any standards, codes, or regulations that apply to the combination of produc ts in the customer?s application or use of the product. at the customer?s request, omron will provide applicable thir d party certification documents identifying ratings and limitation s of use that apply to the products. this information by itself is not sufficient fo r a complete determination of the suitability of the products i n combination with the end product, machine, system, or other application or use. the following are some examples of applica tions for which particular attention must be given. this is not intended to be an exh austive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: ? outdoor use, uses involving potential chem ical contamination or electr ical interference, or conditi ons or uses not described i n this document. ? nuclear energy control systems, combusti on systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. ? systems, machines, and equipment that coul d present a risk to life or property. please know and observe all prohibitions of use applicable to the products. never use the products for an application involving serio us risk to life or property without ensuring that the system as a whole has been designed to address the risks, and that the omron product is properly rated and installed for the intended use within the overall equipment or system. performance data performance data given in this document is provided as a guide for the user in determining suitability and does not constitute a warranty. it may represent the result of omron?s test conditions, and the users mu st correlate it to actual appl ication requirements. actual per formance is subject to the omron warranty and limitations of liability. change in specifications product specifications and accessories may be changed at any time based on improvements and other reasons. it is our practice to change model numbers when published ratings or features are change d, or when significant construction cha nges are made. however, some specifications of the product may be changed without any notice. when in doubt, special model numbers may be assi gned to fix or establish key specific ations for your application on your request. please consult with your omron representative at any time to confirm actual specifications of purchased products. dimensions and weights dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. errors and omissions the information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assum ed for clerical, typographical, or proofreadi ng errors, or omissions. programmable products omron shall not be responsible for the user?s programming of a programmable product, or any consequence thereof. copyright and copy permission this document shall not be copied for sa les or promotions without permission. this document is protected by copyright and is intended solely for use in conjunction with t he product. please notify us before copying or reproducing this document in any manner, for any other purpose. if copying or transmitting this document to another, please cop y or transmit it in its entirety.
authorized distributor: in the interest of prod u ct impro v ement, specifications are s ub ject to change w itho u t notice. cat. no. e401-e1-01 0110 ? omro n corporation 2010 all rights reser v ed. omron corporation industrial automation company omron electronics llc one commerce dri v e scha u m bu rg, il 60173-5302 u.s.a. tel: (1) 8 47- 8 43-7900/fax: (1) 8 47- 8 43-77 8 7 re g ional headquarters omron europe b.v. sensor business unit carl-benz-str. 4, d-71154 nu fringen, germany tel: (49) 7032- 8 11-0/fax: (49) 7032- 8 11-199 contact: www.ia.omron.com tokyo, japan omron asia pacific pte. ltd. n o. 43 8 a alexandra road # 05-05/0 8 (lo bb y 2), alexandra technopark, singapore 119967 tel: (65) 6 8 35-3011/fax: (65) 6 8 35-2711 omron (china) co., ltd. room 2211, bank of china to w er, 200 yin cheng zhong road, p u dong n e w area, shanghai, 200120, china tel: ( 8 6) 21-5037-2222/fax: ( 8 6) 21-5037-2200 this doc u ment pro v ides information mainly for selecting s u ita b le models. please read the instr u ction sheet caref u lly for information that the u ser m u st u nderstand and accept b efore p u rchase, incl u ding information on w arranty, limitations of lia b ility, and preca u tions. csm_3_1_1010


▲Up To Search▲   

 
Price & Availability of E3X-NA11

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X